Cross
reference an
old model with new
Mettler > Sartorius
Entire Sartorius Line
Micro (1-0.1µg)
Cubis Series
ME36-S Balance
CPA26P Balance
SE/ME Series
LE26P Balance
CP2P Series
Analytical (0.1-0.01mg)
Entris Balances
Practum Scales
Quintix Balances
Secura Scales
Cubis Series Genius
- Pro
LE - isoCAL
LA - Pro
CP - Standard
ED - Extend
AZ - Basic
GC - Gem
TE - Economy
Milligram (0.001g)
Entris Scales
Practum Balances
Quintix Scales
Secura Balances
Cubis Series
LE - isoCAL
LA - Pro
CP - Standard
ED - Extend
GK
- Gem
AZ - Basic
BL Scales
TE - Economy
AY123 Scale
GC - Gem
Precision (0.01-0.1g)
Entris Balance
Practum Scale
Quintix Balance
Secura Scale
Cubis Series
LE - isoCAL
LA - Pro
CP - Standard
ED - Extend
AZ - Basic
TE - Economy
BL Portable
AY Scales
GW
- Gem
GP - Gem
Legal for Trade
Diamond
Scale
Pharmacy
Scale
Portable (0.1-0.001g)
TE - Economy
GE -
Gem
ELT Series
AY Scales
High Cap (16kg-64kg)
LE - isoCAL
LA - Pro
CP - Standard
Moisture Analyzers
MA160
MA37
MA100/MA50
MA150
MA35
Explosion-proof
FC-Ex Series
Bench Scales
Signum
Scales
Midrics
Scales
EA/EB
Scales
Filter Balances
MSA2.7S x 0.1ug
MSA6.6 x 1ug
Quintix65 x 10ug
SE2F 2g x 0.1ug
ME5-F 5g x 1ug
CP2P-F 2g x 5ug
LA130S-F x 0.1mg
Industrial Scales
QC Washdown
Floor Scales
Mass Comparators
21g 0.001mg
10kg x 0.01mg
303kg x 1g
3,000kg x 10g
Used / Demo Units
Micro Balances
Analyticals
Accessories
Cal Weights
Mass
Sets
Certified Weights
Specific Gravity
Printer
Static Eliminator
Winwedge Software
Weigh Dishes
Weigh Boats
Beakers
Titration Cups
Moisture Pans
Glassine Paper
AL Dishes
Weighing Canoes
Micro Dishes
Manufacturers
AdamLab
AND Weighing
CAS Scales
Chatillon
Health-o-Meter
Mettler Toledo
My-weigh
Ohaus
Sartorius
Scientech
SECA
Medical
Troemner
Siltec
Tanita
Weigh South
|
 |
Sartorius
FC-Ex Series of Explosion-proof, Intrinsically Safe Scales |

All models feature isoTEST - Fully automatic internal
calibration. At a touch of one key, the scale will calibrate
itself automatically, using a built-in-weight.
Choice of safe or hazardous area power supply (must be ordered by
scale)
IP54 Protection Rating
15 weighing applications standard
User friendly design with a backlit LCD display.
FC-Ex: FM Approved for use in Class 1, Division I, Groups A,B,C,D
hazardous environments
 |
|
Standard
Applications on
FC-Ex Scales
Toggle
between two weight units
Counting
Weighing in Percent
Averaging (animal weighing)
Calculation (equation)
Density Determination
Differential Weighing
Checkweighing
Timer Functions
Totaling
Formulation
Statistics
300 Product Data Memory
User configurable printout |
|
|
|
FC-Ex
Display Features
Easy, User-Friendly Operation
The scale's display prompts the user in plain English for
easy operator guidance.
The keyboard has large, clearly marked keys, which give
you an instant tactile feedback. |
|
|
|
- 2
large tare keys for easy access for right and left hand
users
- 6 application defined soft-keys with the assigned function
clearly shown in the graphic display above each key
- SETUP
key with Windows type menu and application
selections
- Key
for toggling between up to 3 applications
- ABC
key allows for user input of alpha-numeric characters
for user-defined headers and ID numbers
- New
graphic, back-lit LCD shows application related data and
prompts the user through the selected application
|
|
What
does Intrinsically Safe mean? |
Through
the use of special components, materials, ratings and component
layouts, all electric circuits and inter-connected cables are designed
sot that
a) no spark or
b) thermal effect is capable
of causing ignition under fault conditions.
Intrinsically safe equipment can be isolated by Zener barriers from
non-intrinsically-safe circuits for data transfer to the safe area |
Basic
principles of intrinsic safety:
Voltage limitation
Current limitation
Limitation of storable energy |
Advantages
of intrinsically safe protection
Equipment can be calibrated and maintained without removing
power
General purpose wiring methods can be used for connection
to power
No safety permits are required since the area does not need
to be shut down for servicing |
Classification
of Hazardous Locations in the U.S. |
Class |
|
Class
I: Locations in which hazardous
concentrations of flammable gases or vapors exist. |
|
Class
II: Locations which are hazardous due to the presence
of combustible or electrically conductive dust or fibers. |
|
|
Division |
|
Division
1: Present continuously, intermittently or periodically
under normal operating conditions. |
|
Division
2: Not present under normal conditions, but as a result
of an equipment failure, breakdown of containers or abnormal
operation of ventilating equipment. |
|
Groups |
|
Group
A: Atmospheres containing acetylene. |
|
Group
B: Atmospheres containing
hydrogen, gases or vapors of equivalent hazard, such as manufactured
gas. |
|
Group
C: Atmospheres containing ethyl ether vapors, ethylene
or cyclopropane. |
|
Group
D: Atmospheres containing gasoline, hexane, naptha,
benzine, butane, propane, alcohol, acetone, benzol,
lacquer solvent vapors or other natural gases. |
|
 |
For
those areas with ISO concerns the FC-EX scales are capable of
transferring GLP/GMP compliant data via the RS232 interface.
User configurable printouts and calibration data can output to
a printer or computer located outside the hazardous area through
an optional Zener -Barrier (YDI02-Z, YDI03-Z) |
Accessories for FC-EX
Scales |
|
YDI05-ZU2 Zener Barrier
|
|
YDI03-Z Zener Barrier (4x data lines, 4x control lines)
|
|
YTE02-X T-Connector
|
|
YPE05-X Foot Switch
|
|
YPS02-ZKR Safe area power supply
(65 ft cable between scale and power supply)
|
 |
YPS02-XKR Hazardous area power supply
(8ft of intrinsically safe cable x 8ft cable requiring hardwiring
by licensed electrician)
|
|
|
Cable, for connecting Sartorius accessories to FC series scales, 9.8 foot, 12-pin round (male) connector to 25 D-sub (female) connector |
YCC01-0016M3
|
|
|
YDP20-OCE Data Printer with statistics and time/date functions, included cable fits RS232. (Requires the purchase of Zener barrier, YCC01-0016M3 Cable and 6971413 power supply to connect explosion proof balance to printer. Printer must be installed in Safe Area) |
YDP20-OCE
|
6971413 power supply for YDP20-OCE Printer |
6971413
|
|
|
6960FB01 Base Dust Cover for FC06BBE-SX Explosion Proof Balance |
6960FB01
|
|
|
6960FB02 Base Dust Cover for FC2CCE-SX, FC6CCE-HX, FC6CCE-SX or FC12CCE-SX Explosion Proof Balance |
6960FB02
|
|
|
6960LP03 Dust Cover for display, fits all explosion proof scales |
6960LP03
|
|
Hot Buys | Analytical Balances | Baby Scales | Counting
Scales | Industrial
Platform & Bench Scales | Mechanical Balances
Moisture Balances | Pocket Scales | Portable Balances | Precision Toploader
Balances | Price
Computing Scales
Contact Us | Return
Policy | Home | Calibration Weights | Sitemap
Have Questions? Call 978-521-7095 or e-mail us your questions and we
will assist you in your selection.
Copyright © 1995-2017 Precision Weighing Balances , All
Rights Reserved.
https://www.balances.com/, balances.net,
scaleman.com, scalenet.com, weigh.net, weigh.org, analytical-balances.com,
lab-balances.com, moisture-balances.com, & precision-balances.com
are all registered domains of Precision Weighing Balances.
This site is owned and operated by Precision Weighing Balances who